RTI AD-4 Instruções de Operação Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
Audio Distribution System
AD-4
18
CONNECTING REMOTE AUDIO SOURCES
(See “Connecting Remote Audio Sources” diagram)
Audio sources that are located in other areas can have their audio signals
delivered back to the AD-4 and shared among all of the output zones.
NOTE: Local audio inputs (1-4) and remote audio inputs (1-4) are
common, limiting the AD-4 to four audio sources total. Any combination
of local and remote sources may be used, to a maximum of four. For
example, do not plug in a local audio source to local input 1 and remote
audio source to the remote input 1.
WIRING FOR REMOTE AUDIO SOURCES
Use standard Cat-5 cable between the RSP-1 Remote Source Plate and the
RJ-45 jacks on the rear of the AD-4. The RSP-1 has stereo RCA jacks and a
3.5mm mini stereo jack for connecting to the output of the audio source.
In addition to carrying the audio signals, the Cat-5 cable between the
RSP-1 and AD-4 carries IR control of the remote source from an RTI
control system. The control system delivers IR commands to the 3.5mm IR
inputs on the rear of the AD-4.
NOTE: Remote audio sources are available only for the output zones of
the AD-4 to which they are connected. It is not possible to “Y” or split the
audio signals from the RSP-1 to multiple AD-4 units.
NOTE: The AD-4 can accommodate 500 total feet of Cat-5 cable for
each zone. For the most reliable operation, it is best that no single run of
Cat-5 exceeds 250 feet. The correct wiring scheme for the Cat-5 cable is
standard EIA/TIA 568B. Properly terminating the Cat-5 cable is crucial for
the operation of the system.
CONTROLLING REMOTE AUDIO SOURCES
Remote audio sources can be controlled from their own front panel or via
infrared control delivered over the same Cat-5 cable wired to the RSP-
1 Remote Source Panel that is used for the audio signal (see above).
The IR commands used to control the sources come from an RTI control
system which is wired to the IR inputs located on the rear of the AD-4.
Each remote source has an individual IR input for independent control
and commands sent to the “All” input on the AD-4 will allow control of all
remote sources if routing the IR codes is not necessary.
CHAPTER 3 | INSTALLATION AND OPERATION